Integrated cabinet
The integrated cabinet is a solution for micro-data center construction, which integrates data center infrastructure products, including cabinet system, UPS power supply system, air conditioning and refrigeration system, dynamic ring system, fire protection system, integrated wiring system and management system. Multiple subsystems, through the monitoring system to achieve overall management of all systems, simplify the design and construction process, and achieve one-stop deployment and operation management of the data center. The cabinet is fully sealed and can be used in a variety of harsh indoor environments without the need for a separate machine room.
Applications: Business outlets (telecommunications, finance, energy, radio and television, retail, etc.), branches of enterprises, government, education, and medical care, cloud computing edge data center
Features and values:
- ♦ Energy efficient, Efficient power supply, near-end cooling, cold and heat sealed isolation, eliminating local hot spots, PUE will be below 1.5.
- ♦ Rapid deployment, The components are pre-installed and ready to use. No need for decoration, floor and other supporting projects, using integrated air conditioning, no need to install air conditioning outdoor unit, only need one city power line to use.
- ♦ Simplify operation and maintenance, 15 inch large screen, visual image interface operation. Remote monitoring via the network, the interface is simple, and non-professionals can easily operate.
- ♦ Low environmental requirements, No need for renovation, floor and other professional computer room supporting projects, can be deployed in a variety of environments.
- ♦ Flexible expansion, It can realize seamless extension of post-customization.
Structural Analysis:
Product configuration:
Overall plan |
|
Maximum number of supported cabinets |
1-3 |
Support IT load |
≤9KVA |
Installation environment |
Temperature 0-45 ° C, relative humidity 0-90 ° C |
Protection level |
IP20 |
Certification |
CE |
Power distribution system |
|
Power input |
220-240VAC, 60Hz |
Output allocation |
Mains output and UPS output |
UPS capacity |
3KVA, 6KVA, 10KVA |
Bypass repair |
Support |
PDU configuration |
2 horizontal PDUs |
Refrigeration system |
|
Air conditioning type |
One-piece, split |
Cooling capacity |
3KW, 7.5KW |
Air supply method |
Front side air supply, rear return air |
Installation method |
Rack mount |
Emergency device |
2 sets of temperature controlled emergency cooling fans |
Monitoring system |
|
Local interface |
15" touch screen display |
Temperature and humidity |
Support |
Water immersion detection |
Support |
Smoke sensation |
Support |
UPS/Air Conditioning Test |
Support |
Door magnet |
Support |
Alarm mode |
SMS, mail |
Other |
|
Lighting system |
Support |
Fire protection system |
Support |